Analog modulations
R&S
®
SMB100B
91User Manual 1178.3711.02 ─ 08
"checked"
Sets the validity of the RF signal at the output:
●
high: while the signal settles.
●
low: when it is stable (valid).
"cleared"
Generates a single pulse at the beginning of a pulse sequence, e.g.
to synchronize pulse modulation.
Remote command:
[:SOURce<hw>]:PULM:OUTPut:SYNC[:STATe] on page 432
5.4.4.2 Pulse generator > pulse train settings
Option: see Chapter 5.1, "Required options", on page 68.
Access:
1. Select "Modulation" > "Pulse Modulation > Pulse Generator" > "Pulse Mode =
Train".
2. Select "Pulse Train Data".
3. Select an existing file or select "New" to create one.
4. Define the filename.
Select "Edit Pulse Train Data", if the file is empty or to control and change the val-
ues.
5. In the "Edit Pulse Train Data" dialog, enter the pulse on/off times and pulse repeti-
tion values.
6. Select "Save".
A pulse train is a sequence of pulses with user-defined repetition, and pulse on and
off times. Once defined, pulse train settings can be saved in a file. The filename is
user-definable; the file extension (*.pulstrn) is assigned automatically.
When a file is selected, the filename is indicated.
Modulation settings