Remote control commands
R&S
®
SMB100B
463User Manual 1178.3711.02 ─ 08
// SOURce1:LFOutput2:SHAPe:TRAPeze:RISE 0.0001
// SOURce1:LFOutput2:SHAPe:TRAPeze:FALL 0.001
// SOURce1:LFOutput2:SHAPe:TRAPeze:FALL 0.0001
// SOURce1:LFOutput2:SHAPe:TRAPeze:HIGH 0.0005
// SOURce1:LFOutput2:SHAPe TRI
// SOURce1:LFOutput2:SHAPe:PULSe:PERiod 0.1
// SOURce1:LFOutput2:SHAPe:TRIangle:RISE 0.0001
// activate the LF output and select the LF1 as signal source
// configure the LF output signal
SOURce1:LFOutput1:FREQuency:MODE CW
SOURce1:LFOutput1:STATe 1
SOURce1:LFOutput1:SOURce LF1
SOURce1:LFOutput1:INTernal:VOLTage 1
SOURce1:LFOutput1:OFFSet 0.001
LF generator settings............................................................................................ 463
LF sweep settings................................................................................................. 471
12.15.5.1 LF generator settings
With the commands described in this section, you can configure the LF signal source.
[:SOURce]:LFOutput<ch>:BANDwidth?............................................................................464
[:SOURce]:LFOutput<ch>:FREQuency.............................................................................464
[:SOURce<hw>]:LFOutput<ch>:PERiod?..........................................................................464
[:SOURce<hw>]:LFOutput:FREQuency:MANual............................................................... 465
[:SOURce<hw>]:LFOutput:FREQuency:MODE................................................................. 465
[:SOURce<hw>]:LFOutput:FREQuency:STOP.................................................................. 466
[:SOURce<hw>]:LFOutput:FREQuency:STARt..................................................................466
[:SOURce]:LFOutput<ch>[:STATe]................................................................................... 466
[:SOURce]:LFOutput<ch>:INTernal:VOLTage....................................................................466
[:SOURce]:LFOutput:OFFSet.......................................................................................... 466
[:SOURce]:LFOutput<ch>:SOURce................................................................................. 467
[:SOURce]:LFOutput:SIMPedance...................................................................................467
[:SOURce]:LFOutput<ch>:SOURce:PATH........................................................................ 467
[:SOURce]:LFOutput:VOLTage........................................................................................ 468
[:SOURce<hw>]:LFOutput<ch>:SHAPe............................................................................468
[:SOURce<hw>]:LFOutput<ch>:SHAPe:PULSe:DCYCle....................................................468
[:SOURce<hw>]:LFOutput<ch>:SHAPe:PULSe:PERiod.....................................................469
[:SOURce<hw>]:LFOutput<ch>:SHAPe:PULSe:WIDTh......................................................469
[:SOURce<hw>]:LFOutput<ch>:SHAPe:TRAPeze:FALL.................................................... 469
[:SOURce<hw>]:LFOutput<ch>:SHAPe:TRAPeze:HIGH....................................................469
[:SOURce<hw>]:LFOutput<ch>:SHAPe:TRAPeze:PERiod................................................. 470
[:SOURce<hw>]:LFOutput<ch>:SHAPe:TRAPeze:RISE.................................................... 470
[:SOURce<hw>]:LFOutput<ch>:SHAPe:TRIangle:PERiod..................................................470
[:SOURce<hw>]:LFOutput<ch>:SHAPe:TRIangle:RISE..................................................... 470
SOURce subsystem