Instrument Function
R&S
®
SMB100A
192Operating Manual 1407.0806.32 ─ 13
Example:
SOUR:LFO:SWE:FREQ:MODE AUTO
TRIG:LFFS:SWE:SOUR SING
TRIG:LFFS
Remote command:
[:SOURce]:LFOutput:SWEep[:FREQuency]:EXECute on page 314
:TRIGger<hw>:LFFSweep:IMMediate on page 408
:TRIGger<hw>:LFFSweep on page 407
:TRIGger<hw>[:IMMediate] on page 411
Reset Sweep - LF Sweep
Resets the sweep. The start frequency is set and the next sweep starts from there.
Remote command:
[:SOURce<hw>]:SWEep:RESet[:ALL] on page 387
Start Freq - LF Sweep
Sets the start frequency.
Remote command:
[:SOURce]:LFOutput:FREQuency:STARt on page 313
Stop Freq - LF Sweep
Sets the stop frequency.
Remote command:
[:SOURce]:LFOutput:FREQuency:STOP on page 314
Current Freq - LF Sweep
Displays the current frequency.
If "Step" is set, the frequency for the next frequency step of the sweep is entered here.
Remote command:
[:SOURce]:LFOutput:FREQuency:MANual on page 312
Spacing - LF Sweep
Selects linear or logarithmic sweep spacing.
Remote command:
[:SOURce]:LFOutput:SWEep[:FREQuency]:SPACing on page 317
Shape - LF Frequency Sweep
Selects the cycle mode for a sweep sequence (shape)
Modulation Generator and LF Output