Remote Control Commands
R&S
®
SMB100A
427Operating Manual 1407.0806.32 ─ 13
Example:
STEReo:DIRect? "PS"
Response: "RDS Test"
STEReo:DIRect "PS-TABLE=<Table>"
STEReo:DIRect? "PS-TABLE"
Selects the character set table tobe used for the display of the RDS program service (PS)
name in the receiver.
The information concerning the character set is transmitted in segment 0 of the PS. Seg-
ment 0 is repeatedly transmtted if the value for PS-TABLE > 0. For PS-TABLE=0 no
information concerning the character set is transmitted.
Setting parameters:
<Table> 0 | 1 | 2 | 3
0
no information concerning the character set table in the PS
1
table E.1 is used
2
table E.2 is used
3
table E.3 is used
Example:
STEReo:DIRect "PS-TABLE=2"
The information concerning the character set is transmitted in
segment 0 of the PS in group 0A. To this end, segment 0 is trans-
mitted repeatedly. At the first transmission segment 0 contains the
information about the character set, at the second transmission
segment 0 contains the first two characters of the PS.
STEReo:DIRect "PTY=<PTY>"
STEReo:DIRect? "PTY"
Sets or reads the program type (PTY).
Setting parameters:
<PTY> Note: A two-digit value must always be set. A leading zero, if any,
must also be specified.
Range: 00 to 31 (ASCII coded decimal numbers)
Example:
STEReo:DIRect "PTY=08"
Sets the program type to be transmitted to "08".
Example:
STEReo:DIRect? "PTY"
Response: "08"