CHAPTER 2. MMC Programming
2-124
© SAMSUNG Electronics Co., Ltd.
[409] TRUNK STATUS READ
This is a READ-ONLY MMC. Allows the status of trunks to be read in a format that will
enable the servicing personnel to quickly identify the ownership and position of a trunk.
No Type Description
00 PORT Port Number (Cabinet/Slot/Port)
01 TYPE LOOP, GND, E&M, DID, BRI, PRI, VOIP
02 1A2 EMULATE 1A2 Emulation On/Off
03 TRK FORWARD Trunk Forward On/Off
04 LINE CO/PBX
05 DIAL DTFM/Dial Pulse
06-11 TOLL TYPE 1-6 Ring Plan Toll Restriction (1-6)
12-17 RING PLAN 1-6 Ring Plan Ring Destination (1-6)
18 MOH SOURCE MOH Source
19 DISA LINE DISA Status
DEFAULT DATA
FOLLOWS TRUNK
ACTION DISPLAY
1)
Press Transfer button and enter 409.
[701] TRK STATUS
PORT:C1-S5-P01
2) Enter trunk number via dial keypad. (e.g., 704)
[704] TRK STATUS
PORT:C1-S5-P04
Press Volume button to make selection and press
Right Soft button to advance cursor.
3) Enter desired option 00-19. (e.g., 01)
[704] TRK STATUS
TYPE:LOOP TRUNK
Press Volume button to make selection.
4) Press Transfer button to save and exit.
OR
Press Speaker button to advance to next MMC.