EasyManua.ls Logo

Samsung OfficeServ 7000 Series - Mgi Parameters

Samsung OfficeServ 7000 Series
487 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OfficeServ 7000 Series Call Server Programming Manual
© SAMSUNG Electronics Co., Ltd.
2-361
[831] MGI PARAMETERS
This MMC provides network configuration of the MGI/OAS card (s) in the system.
No Parameter Description
0 IP ADDRESS Specifies the IP address for the MGI card.
1 GATEWAY Specifies the designated IP gateway address used for contacting
IP devices beyond the local subnet.
2 SUB MASK Specifies the IP subnet mask. This parameter is used by the system to
calculate the range of IP devices (subnet) that are within direct reach
of the MGI. (without having to go through the designated network IP
gateway)
3 IP TYPE Specifies if the system will be routing data over a public or private
network.
4 LOCAL RTP Specifies local rtp port The default value is 30000 and the value range
is between 10000 and 60000. If you use MPS function, the value must
be not duplicated with MMC861 MPS local rtp port.
This option is only shown in case of installed MGI 64/MGI16 card
5 CARD RESET Reboots MGI card.
6 PUB IP1 Pulbic IP Address is only used for VoIP signaling protocols in a
NAT network . NAT system binds IP Address with Public IP and
processes a voice stream. See System IP Type on MMC 830.
7 PUB RTP1 Public RTP Port which NAT system binds a private RTP port with
8 PUB IP2 Pulbic IP Address is only used for VoIP signaling protocols in a
NAT network . NAT system binds IP Address with Public IP and
processes a voice stream. See System IP Type on MMC 830.
9 PUB RTP2 Public RTP Port which NAT system binds a private RTP port with
10 PUB IP3 Pulbic IP Address is only used for VoIP signaling protocols in a
NAT network . NAT system binds IP Address with Public IP and
processes a voice stream. See System IP Type on MMC 830.
11 PUB RTP3 Public RTP Port which NAT system binds a private RTP port with
12 QOS MONIT. Specifies use of QOS. This option is only shown in case of installed
MGI card. (not supportted MGI16/ 64)
13 MAC ADDR Displays the MAC address of an MGI card
This option is only shown in case of installed MGI64/MGI16 card.
14 IP VERSION Specifies MGI IP version is Ipv4 / Ipv6. (This option may not be
available in certain OfficeServ models.)
If MP-MGI port (the embedded MGI) is selected, IP ADDRESS, GATEWAY, SUB
MASK, CARD RESET parameters can not be set in this MMC because these
parameters and the system values are the same. The system values can be
referred in MMC830

Table of Contents

Other manuals for Samsung OfficeServ 7000 Series

Related product manuals