CHAPTER 2. MMC Programming
2-54
© SAMSUNG Electronics Co., Ltd.
[204] COMMON BELL CONTROL
Determines whether the common bell relay contacts have an interrupted or continuous
closure when activated. If interrupted is chosen, the relay follows an internal Trunk Line
ring pattern of one second closed followed by three seconds open.
CONDITIONS
When the common bell is not used for night time ring, the common bell must be set to a
station group so that all stations in the group ring.
DEFAULT DATA
CONTINUOUS
ACTION DISPLAY
1) Press Transfer button and enter 204.
Display shows current setting:
[3801]COM. BELL
CONTINUOUS
2) Dial common bell number.
OR
[3801]COM. BELL
CONTINUOUS
Press Volume button to make selection of common
bell numbers and press Right Soft button to advance
cursor.
3) Dial 0 for continuous or 1 for interrupted operation.
OR
[3802]COM. BELL
INTERRUPTED
Use Volume button to scroll through options and press
Right Soft button to return to step 2.
4) Press Transfer button to save and exit.
OR
Press Speaker button to save and advance to next
MMC.
RELATED ITEMS
MMC 203 ASSIGN UA DEVICE
MMC 601 ASSIGN STATION GROUP