[843] MPS OPTIONS
This MMC provides network configuration of MPS (Media Proxy Server) in the system.
This option can be shown in some OfficeServ system.
No Parameter Description
0 LOCATION Located Cabinet and slot number of MPS.
1 IP ADDRESS Specifies the IP address for the MPS.
2 GATEWAY Specifies the designated IP gateway address used for contacting IP
devices beyond the local subnet.
3 SUB MASK Specifies the IP subnet mask. This parameter is used by the system to
calculate the range of IP devices (subnet) that are within direct reach of the
MPS. (without having to go through the designated network IP gateway)
4 IP TYPE Specifies if the system will be routing data over a public or private
network.
5 LOCAL RTP Local RTP Port
6 CARD RESET Reboots MPS
7 PUBLIC IP1 Pulbic IP Address is only used for VoIP signaling protocols in a NAT
network . NAT system binds IP Address with Public IP and processes a
voice stream. See System IP Type on MMC 830
8 PUBLIC RTP1 Public RTP Port which NAT system binds a private RTP port with
9 PUBLIC IP2 Pulbic IP Address is only used for VoIP signaling protocols in a NAT
network . NAT system binds IP Address with Public IP and processes a
voice stream. See System IP Type on MMC 830
10 PUBLIC RTP2 Public RTP Port which NAT system binds a private RTP port with
11 PUBLIC IP3 Pulbic IP Address is only used for VoIP signaling protocols in a NAT
network . NAT system binds IP Address with Public IP and processes a
voice stream. See System IP Type on MMC 830
12 PUBLIC RTP3 Public RTP Port which NAT system binds a private RTP port with
13 IP VERSION Specifies MPS IP version is IPv4 / IPv6.
If MP-MPS (the embedded MPS) is selected, parameters such as IP ADDRESS,
GATEWAY, SUB MASK, CARD RESET can not be set in this MMC because
these parameters and the system values are the same.
The system values can be referred in MMC 830.
CONDITIONS
This MMC cannot be accessed unless MMC861 MPS SERVICE is enable.