OfficeServ 7000 Series Call Server Programming Manual
© SAMSUNG Electronics Co., Ltd.
2-307
[759] CLI RINGING
This MMC assigns a specific CLI number received from the central office to a specific ring
plan destination. Also allows you to reject a specific CLI number and assign priorities.
There are 9 priority levels: priority 1 is the highest and priority 9 is the lowest.
It also allows you to select the ring tone heard at a phone when called by a specific CLI
number. There is also a cadence control option to perform a similar function for SLTs.
There are eight ring tones available along with a Follow Station (NO) option. There are
five cadences and a Follow Station option (NO) for SLTs. The CLI
DEFAULT DATA
NONE
Option Description
CLI CLI number to be received from the central office. Up to 16 digits may be
entered.
REJ CLI call reject option. When this sets YES, if a call comes that matched CLI
number and CLI field then the system will be reject call.
PRI CLI priority option. There are 9 priority levels: priority 1 is the highest and
priority 9 is the lowest. When calls into station group come and group
members are all busy, the system will assign a priority to the CLI number so
that calls from a high priority CLI number will be placed at the front of the
group queue.
If this option sets NO, the longest call that placed at the group queue has
the highest priority.
R1: XXX, R2: XXX,
R3: XXX, R4: XXX,
R5: XXX, R6: XXX
Ring plan and destination during each ring plan. The destination can be a
station, station group.
TONE Ring Tone options for a specific CLI at DGP/ITP. (NO, 1~8)
No Calls will ring with the phone users choice of ring frequency.
1~8 Calls from the programmed CLI number will ring phones with this
ring frequency.
CAD
Ring Cadence options for a specific CLI Number at SLTs (NO, 1~5)
No
Calls will ring with the normal SLT ring cadences.
1~5 Calls from the programmed CLI number will ring SLTs with this ring
cadence.
1: intercom ring, 2:CO ring, 3: DOOR ring, 4:ALARM, 5:CALLBACK

Table of Contents