OfficeServ 7000 Series Call Server Programming Manual
© SAMSUNG Electronics Co., Ltd.
2-435
[863] SYSTEM NODE INFORMATION
This MMC is the program that specifies the system information of SPNET (Samsung
Protocol Networking). It is useful when many systems are consisted through SPNET and
interlocked with LCR. There are maximum 2000 entries.
No Option Description
0 ACCESS NUM Other System’s ID
1 IP ADDR Other System’s IP address
2 TEL NUMBER Rerouting Trunk Number (excluding VoIP Trunk Number).
If SPNET function is not work, Call is rerouted through this trunk
3 MAX COUNT If you dial a valid digit string until Max Count number, the system
set up call.
4 NO MGI No: Use MGI as of old, Yes: Don’t use MGI
(This option can be shown in case that MMC 861 ‘MPS
SERVICE’ set to ENABLE)
SPNET is VoIP Network function developed by Samsung. (it is not standard
function.)
CONDITIONS
LINK ID should not be inputted at MMC 820 SYSTEM LINK and ACCESS NUMBER &
TEL NUMBER should be inputted at LCR table.
ACTION DISPLAY
1) Press Transfer button and enter 863.
(0001) ACCESS NUM
2) Enter the node entry number.
(0001) ACCESS NUM
Press Volume button to select and press Right Soft
3) Enter the option number
(0001) ACCESS NUM
Press Volume button to select and press Right Soft
button to store.
4) Enter the access number.
(0001) ACCESS NUM
1