CHAPTER 2. MMC Programming
2-2
© SAMSUNG Electronics Co., Ltd.
2.2 Programming Procedure
This section describes a procedure of each program. Refer to the programming procedure
corresponding to the MMC.
[100] STATION LOCK
Allows the system administrator or technician to lock or unlock an individual station or all
stations simultaneously. The three options are as follows:
No Type Description
0 UNLOCKED Unlocks a locked station.
1 LOCKED OUT The phone cannot make calls outside the system. It can however make
and receive intercom calls and receive incoming Trunk Line calls.
When in this mode the Hold button will flash slow RED.
2 LOCKED ALL The phone cannot make or receive any calls. When in this mode the
Hold button will light steady RED.
CONDITIONS
Check if the station lock function is disabled at MMC 301 ASSIGN STATION COS’.
If so, the station cannot be locked, but a locked station can be unlocked.
A station can be locked or unlocked under any condition when the station is in
Operator Level Programming or Technician Level Programming.
DEFAULT DATA
ALL STATIONS UNLOCKED