[500] SYSTEM-WIDE COUNTERS
Used to set the values of the system counters. The counters are listed below with a brief
description of each.
No Counter Default Description
0 ALARM REM.
CNTER
5 The number of times that an alarm reminder will ring a
station before cancelling. RANGE = 1-99.
1 AUTO RDL
COUNTER
5 The number of times the system will redial an outside
number after the auto redial feature has been activated.
RANGE = 1-99.
2 DISA CALL CNTER 99 Sets the maximum number of intercom calls that can be
made after accessing a DISA line. RANGE = 1-99.
3 DISA LOCK CNTER 3 Number of attempts the system will allow to incorrectly
access a DISA line before locking out the DISA line.
RANGE = -99
4 NEW CALL
COUNTER
99 Number of times the system will allow a user to signal
New Call on a Trunk line during one call.
RANGE = 1-99.
5 UCDS VISUAL
ALARM
0 Used to set the Visual alarm threshold. It is triggered
when the number of calls waiting to be answered in the
UCD group reaches this value. RANGE = 0-25.
6 UCDS AUDIO ALARM 0 Used to set the Audio alarm threshold. It is triggered
when the number of calls waiting to be answered in the
UCD group reaches this value. RANGE = 0-25.
7 UCD CS LEVEL 1 0 Provides call wait indication level 1 if number of calls
waiting to be answered in UCD group reaches this
value. RANGE = 0-25.
8 UCD CS LEVEL 2 0 Provides call wait indication level 2 if number of calls
waiting to be answered in UCD group reaches this
value. RANGE = 0-25.
DEFAULT DATA