[503] TRUNK-WIDE TIMERS
Allows certain trunk timer values to be changed on a per-trunk basis or for all trunks.
No Item Description Range
00 ANS.BAK TM ANSWER BACK TIME. This timer is used for certain
types of E&M Signaling and does not affect normal
CO lines.
0-2500 MSEC
01 CLEARING This timer ensures that a call is fully disconnected at
the CO by preventing CO access outgoing or
receiving incoming ring between a disconnect and
the expiration of this timer.
100-9900 MSEC
02 CO SUPV TM CO SUPERVISION TIME. this is the minimum
length of loop open disconnect received from the
CO that will be seen as a valid hang up on the
system.
10-2500 MSEC
03 DTMF DUR. DTMF DURATION. This is the length of the DTMF
digits that will be sent to the CO on this line.
100-9900 MSEC
04 F-DGT DELY First-DIGIT DELAY. This is the length of time the
system will wait for CO line conditions to stabilize
after seizure before sending DTMF digits.
100-9900 MSEC
05 FLASH TIME This is the duration of the momentary open sent on
a circuit when FLASH key is pressed.
20-2500 MSEC
06 NO RING TM This is the length of time the system will wait after
detecting a ring burst on a line before deciding the
call has disconnected.
1-25 SEC
07 PAUSE TIME This is the length of time the system will wait before
sending the next digit for a pause in a speed dial
bin.
1-25 SEC
08 PRS DET TM This means the duration of PRS signal pulse. If the
PRS signal is reversed when opposite party is
answered and maintain the status before the
opposite party disconnect the call, the PRS DET TM
must be set to 0.
0-2500 MSEC
09 RNG DET TM RING DETECT TIME. This is the minimum length of
ring signal the system will regard as a valid ring.
10-2500 MSEC
10 WINK TIME This is the duration of the acknowledgment signal
that the system will send on an E&M circuit
100-300 MSEC
11 MF/DP INT This is the interval between sending digit. In case of
DTMF signal, over the 500ms will be serviced as
100 ms.
100-9900 MSEC
12 MFR DLY TM This is a delay time to allocate the MFR after
incoming trunk is detected. This is to prevent the
wrong detection of DTMF signal by noise.
0-25 SEC
13 DISA ANSWR This is a delay time to answer the DISA trunk call or
to answer the trunk when TRK AUTO ANSWER is
set to ON (MMC400).
0-9 SEC