[804] SYS I/O MODE
This is the program to designate the MODEM port of the system.
SERVICE: Service type
Number Service Type Description
00 NOT USE Not using
01 IT IT, Remote Programming
BAUD RATE: Transmission time
Option Setting Value
0
4800 bps
1
9600 bps
2
19200 bps
3
38400 bps
CHAR LENGTH: Length of the characters
Option Setting Value
7 7 bits
8
8 bits
PARITY: Parity bit
Option Setting Value
0
NONE
1 ODD
2
EVEN
RETRY COUNT: Number of retry attempts (01~99)
STOP BIT: Stop bit
Option Setting Value
1 1 bit
2 2 bit

Table of Contents