OfficeServ 7000 Series Call Server Programming Manual
© SAMSUNG Electronics Co., Ltd.
2-399
[842] SIP STATION INFORMATION
This MMC provides a means of registering the SIP with the OfficeServ 7000 series system.
No. Parameter Description
0 REGISTERED This indicates whether the corresponding standard SIP terminal is
registered.
-
IP ADDRESS IP address of IP phone
0 USER ID When phone is registered, user ID for checking user
2 USER PSWD When phone is registered, user password for checking user
- TONE SRC Designate whether to use the holding tone of the system or to use
the holding tone of the SIP terminal when connecting the call via
the SIP terminal.
0. USE SYSTEM TONE = Use the tone of the system for the
holding tone and for the ring back tone in some ring back status
(CALLBACK, etc.). When using the tone of the system, in case
of the calls which do not use the MGI such as the call between
the SIP terminals or the call with the IP phone, the holding tone
(ring back tone) is emitted by allocating the MGI.
1. USE SIPP TONE = Use the own tone of the SIP terminal.
- CALL WAIT This indicates whether to receive the second call without treating it
as the busy status when the second call is received in the SIP
terminal. (DISABLE / ENABLE)
8 PHONE TYPE This indicates the manufacturer of the standard SIP terminal.
In case of the terminals other than the Samsung standard SIP
terminals, registration is limited to the number allocated according
to the LICENSE KEY entered in the MMC860.
(DISCONNECTED / SAMSUNG PHONE / OTHER SIP PHONE)
9 PUB IPADDR These values indicate the IP address and port number of terminals
or access pointers sending REGISTER messages. The ‘PUB
IPADDR’ value can be different from the ‘IP ADDRESS’.
10 PUB PORT
11 SIG PORT This indicates the port and transport protocol that is used for
signaling by SIP terminals. If signaling port is stored at DB, the SIP
phone can transmit and receive signal although the system restart.
12 PROTOCOL