CHAPTER 2. MMC Programming
2-158
© SAMSUNG Electronics Co., Ltd.
[432] SET H-TRK
This MMC is used to select the type of Signaling for each H- trunk.
There are three operation types available. (E & M, DID, R/D)
MMC [432]
This option may not be available in certain OfficeServ models.
DEFAULT DATA
E&M
ACTION DISPLAY
1)
Press Transfer button and enter 432.
[701] SET H-TRK
E&M
2)
Enter desired trunk number. (e.g., 705)
[705] SET H-TRK
E&M
Press Volume button to make selection.
Press Right Soft button to move cursor.
OR
[ALL] SET H-TRK
E&M
3) Press Volume button to select trunk type and press
Right Soft button to move cursor.
[705] SET H-TRK
DID
4) Press Transfer button to save and exit.
OR
Press Speaker button to advance to next MMC.
RELATED ITEMS
NONE