No Option Description Default
10 ITP VERS
UPGRADE
1. START (HHMM): IP-based phone software
automatic upgrade start time.
2222
(Disable)
2. INTERVAL: IP-based phone software automatic
upgrade interval time.
10 seconds.
11 MGI ALIVE
PERIOD
Set the time interval of checking the link connection of
MGI card and the system.
05 SEC
12 DATA CARD IPC Designate whether to execute the IPC with the DATA
card if the DATA card is mounted on the system.
YES
13 ITP RING
VOLUME
Designate the Ring Volume value of the IP phone as
eight stages.
LEVEL 1: 02
LEVEL 2: 03
LEVEL 3: 04
LEVEL 4: 05
LEVEL 5: 06
LEVEL 6: 07
LEVEL 7: 08
LEVEL 8: 09
14 ITP MAX TX LIMIT TX level which is in case of using MGI or not can be
restricted for voice quality of IP Phone.
NO
15 WIP DSP PARA Designate the DSP parameter of the WLAN phone
- M-FRAME: The length of voice data.
- ECHOCNCL: The option for using Echo Cancel
function.
40MSEC
ENABLE
16 ALL IDLE ITP OUT All IP-based phone supporting IDLE MODE can logout
except IP LOUT COS is limited and phone is busy
state.
Type :
0) MMC COMMAND : All IP-based phone logout
manually only.
1) AUTO TIME : All IP-based phone logout
automatically at set time.
0
TIME (HHMM) : All IP-based phone automatic logout
time.
22:00
LOGOUT NOW : All IP-based phone logout now. NO
23 PUBLIC IP SET
No MMC830 MMC831 MMC843
1 (IP SET 1) SYS
PUBLIC IP1
PUB IP1
PUB RTP1
PUB IP1
PUB RTP1
2 (IP SET 2) SYS
PUBLIC IP2
PUB IP2
PUB RTP2
PUB IP2
PUB RTP2
3 (IP SET 3) SYS
PUBLIC IP3
PUB IP3
PUB RTP3
PUB IP3
PUB RTP3
1(IPSET 1)