Transponder
7.4 MDS D124
SIMATIC RF200
200 System Manual, 07/2015, J31069-D0227-U001-A9-7618
The temperature class or the maximum surface temperature depends on the maximum
ambient temperature. The relationship between temperature class (gas) or maximum surface
temperature (dust) can be found in the following table.
Table 7- 9 Ambient temperature
Ambient temperature range
Temperature class
Max. surface temperature
-25 ... +150 ℃
T3
T180
-25 ... +100 ℃ T4 T130
-25 ... +65 ℃
T5
T95
-25 ... +50 ℃ T6 T80
Note
Safety markings for hazardous areas
Since there is not enough space on the MDS D124 for the safety mark, this is supplied as a
label with the device.
This must be affixed immediately
next to the MDS D124 so that the label clearly relates to
the device.
WARNING
Gefahr durch elektrostatische Entladungen
Potential electrostatic charging hazard
Danger potentiel de charges électrostatiques
Note
Installation and operating conditions for hazardous areas:
•
Use of the device in the vicinity of processes generating high charges is not allowed.
•
The device must be installed so that it is mechanically protected.
•
For applications requiring devices of category 1, the device must be mounted on a
grounded, conductive base.
•
It must only be cleaned with a damp cloth.
•
The device is suitable for use in atmospheres containing dust, however not for full
immersion in dust.

Table of Contents

Other manuals for Siemens SIMATIC Ident

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC Ident and is the answer not in the manual?

Siemens SIMATIC Ident Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC Ident
CategoryOther
LanguageEnglish

Related product manuals