Transponder
7.10 MDS D200
SIMATIC RF200
226 System Manual, 07/2015, J31069-D0227-U001-A9-7618
6GT2600-1AD00-0AX0
Read cycles (at < 25 ℃)
> 10
14
Write cycles (at < 25 ℃)
> 10
6
Data retention time (at < 25 ℃)
> 10 years
Write/read distance (S
g
) Dependent on the reader used, see section "Field
data (Page 37)"
MTBF (Mean Time Between Failures)
2 x 10
5
hours
Mechanical specifications
Housing
Material PET
Color White
Recommended distance to metal
> 25 mm
Power supply
Inductive, without battery
Permitted ambient conditions
Ambient temperature
During operation -20 to +60 ℃
During transportation and storage -20 to +60 ℃
Degree of protection to EN 60529
IP67
Shock-resistant to EN 60721-3-7 class 7M3
ISO 10373 / ISO 7810
1)
Vibration-resistant to EN 60721-3-7, class 7M3
ISO 10373 / ISO 7810
1)
Torsion and bending load
ISO 10373/ISO 7816-1
Design, dimensions and weight
Dimensions (L x W x H)
85 x 54 x 0.8 mm
Weight
5 g
Type of mounting
Fixing pocket
Glued
1)
The values for shock and vibration are maximum values and must not be applied continuously.