Transponder
7.15 MDS D421
SIMATIC RF200
248 System Manual, 07/2015, J31069-D0227-U001-A9-7618
Flush-mounting of MDS D421 in metal with tools
Figure 7-36 Flush-mounting of MDS D421 in metal with tools
b
1
0.5 x 45°
b
2
0.3 x 45° or R 0.3
d
1
10 (-0.04.. -0.13)
d
2
10 (+0.09... 0)
t
1
4.5 (-0... -0.1)
t
2
4.6 (+0.2... 0)
All dimensions in mm
Note
Installation instruction
The MDS should not protrude out of the locating hole; it must be flush with the outside
contour.
The mounting instructions of the MDS and the conditions associated with the application
(e.g. peripheral speed, temperature, and use of coolant) must be observed during the
installation.
Mounting information for adhesion
Drill installation hole
The adhesive surfaces must be dry, free from dust, oil, stripping agents and other
impurities
Apply adhesive according to the manufacturer's processing instructions
Press in MDS D421 using your finger; antenna side to the outside (see figure "Flush-
mounting of MDS D421 in metal with tools")
Remove residues of adhesive
Allow to cure according to the manufacturer's instructions
Flush-mounting of MDS D421 in metal with tools