RF200 system planning
4.3 Installation guidelines
SIMATIC RF200
68 System Manual, 07/2015, J31069-D0227-U001-A9-7618
To avoid any influence on the field data, the distance a should be ≥ 150 or 200 mm.
Table 4- 25 Reduction of field data due to metal, range as %: Transponder and RF290R with ANT
D5
Antenna on metal
(metal plate)
antenna flush-
mounted in metal
(all round 150 mm)
1)
flush-mounted in metal;
distance all round 20 mm
45 40
1)
flush-mounted in metal;
65 60
1)
flush-mounted in metal;
55 50
1)
1)
1)
flush-mounted in metal;
45 40
on metal, distance 25 mm 65 60
1)
on metal, distance 15 mm 75 70
1)
1)
flush-mounted in metal;
45 40
1)