EasyManuals Logo

Siemens SIMATIC S7-300 Module data Reference Manual

Siemens SIMATIC S7-300 Module data
574 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
Contents
xiii
Programmable Logic Controllers S7-300 Module Data
A5E00105505-03
3.27 Relay Output Module SM 322;
DO 16 x Rel. 120/230 VAC; (6ES7322-1HH01-0AA0) 3-93 . . . . . . . . . . . . . . . .
3.28 Relay Output Module SM 322; DO 8 x Rel. 230 VAC;
(6ES7322-1HF01-0AA0) 3-96 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.29 Relay Output Module SM 322;
DO 8 x Rel. 230 VAC/5A; (6ES7322-5HF00-0AB0) 3-100 . . . . . . . . . . . . . . . . . .
3.29.1 SM 322; DO 8 x Rel. 230 VAC/5A parameterization 3-104 . . . . . . . . . . . . . . . . . .
3.29.2 Behavior and Diagnostics of the SM 322; DO 8 x 230 VDC/0.5 A 3-104 . . . . . .
3.29.3 Interrupts of the SM 322; DO 8 x Rel. 230 VAC/5A 3-105 . . . . . . . . . . . . . . . . . . .
3.30 Relay Output Module SM 322; DO 8 x Rel. VAC 230/5 A;
(6ES7322-1HF10-0AA0) 3-106 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.31 Digital Input/Output Module SM 323;
DI 16/DO 16 x 24 VDC/0.5 A; (6ES7323-1BL00-0AA0) 3-110 . . . . . . . . . . . . . . .
3.32 Digital Input/Output Module SM 323;
DI 8/DO 8 x VDC 24/0.5 A; (6ES7323-1BH01-0AA0) 3-113 . . . . . . . . . . . . . . . . .
3.33 Digital Input/Output Module SM 327;
DI 8/DX 8 x DC 24 V/0.5 A; parameterizable (6ES7327-1BH00-0AB0) 3-116 . .
3.33.1 Assigning Parameters to the SM 327; DI 8/DX 8 x VDC 24/0.5 A 3-119 . . . . . .
4 Analog Modules 4-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1 Module Overview 4-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2 Sequence of Steps from Choosing to Commissioning the Module 4-8 . . . . . .
4.3 Analog Value Representation 4-9 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.1 Analog Value Representation for Analog Input Channels 4-10 . . . . . . . . . . . . . .
4.3.2 Analog Value Representation for Analog Output Channels 4-24 . . . . . . . . . . . .
4.4 Setting the Measuring Method and Measuring Ranges of Analog Input
Channels 4-28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5 Behavior of the Analog Modules 4-31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.5.1 Effect of Supply Voltage and Operating Mode 4-31 . . . . . . . . . . . . . . . . . . . . . . .
4.5.2 Effect of Range of Values of the Analog Values 4-32 . . . . . . . . . . . . . . . . . . . . . .
4.5.3 Effect of Operational Limit and Basic Error Limit 4-34 . . . . . . . . . . . . . . . . . . . . .
4.6 Conversion, Cycle, Setting and Response Time of Analog Modules 4-35 . . . .
4.7 Analog Module Parameter Assignment 4-39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.1 Parameters of the Analog Input Modules 4-40 . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.2 Parameters of the Analog Output Modules 4-43 . . . . . . . . . . . . . . . . . . . . . . . . . .
4.7.3 Parameters of the analog input/output modules 4-44 . . . . . . . . . . . . . . . . . . . . . .
4.8 Connecting Sensors to Analog Inputs 4-45 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.9 Connecting Voltage Sensors 4-50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.10 Connecting Current Sensors 4-51 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.11 Connecting Resistance Thermometers and Resistors 4-53 . . . . . . . . . . . . . . . .
4.11.1 Connecting resistance thermometers to the SM 331; AI 8 x 13 bits 4-56 . . . . .
4.12 Connecting Thermocouples 4-58 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.13 Connecting Loads/Actuators to Analog Output 4-66 . . . . . . . . . . . . . . . . . . . . . .
4.14 Connecting Loads/Actuators to Voltage Outputs 4-67 . . . . . . . . . . . . . . . . . . . . .
4.15 Connecting Loads/Actuators to Current Outputs 4-70 . . . . . . . . . . . . . . . . . . . . .

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)

Related product manuals