B.2 Parameter Table
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07) 363
Parameter List
B
E4-14
<22>
Motor 2 Slip
Compensation
Gain
Function is the same as C4-01 for motor 1.
Magnifies the torque compensation gain. This
parameter does not typically require
adjustment, however, adjustments can be
made as follows:
Increase the setting when using a long motor
cable.
When using a motor with a smaller capacity
than the drive (the largest motor being used),
increase this setting.
If the motor begins to vibrate, adjust the value
set so that the output current doesn't exceed
the drive's rated output current when
operating at low speeds.
0.00 to
2.50
1.00
<2>
AA 341
When operating at low speeds, adjust
this setting such that the output current
does not exceed the rated output
current for the drive.
E4-15
Torque
Compensation
Gain - Motor 2
Magnifies the torque compensation gain. This
parameter does not typically require
adjustment, however adjustments can be
made as follows:
When the motor cable is long, increase the
setting.
When using a motor with a smaller capacity
than the drive (the largest motor being used),
increase this setting.
If the motor begins to vibrate, adjust the value
such that the output current does not exceed
the drive's rated output current when
operating at low speeds.
1.00 to
2.50
1.10 A A 341
E4-16 DELETE Available for Simple V/F with PG. - - - −− -—
E4-17 DELETE Available for Simple V/F with PG. - - - −− -—
E4-18 DELETE Available for Simple V/F with PG. - - - −− -—
E4-19 DELETE Available for Simple V/F with PG. - - - −− -—
E4-20 DELETE Available for Simple V/F with PG. - - - −− -—
E4-21 DELETE Available for Simple V/F with PG. - - - −− -—
E4-22 DELETE Available for Simple V/F with PG. - - - −− -—
E4-23 DELETE Available for Simple V/F with PG. - - - −− -—
E4-25 DELETE Available for Simple V/F with PG. - - - −− -—
E4-27 DELETE Available for Simple V/F with PG. - - - −− -—
No. Name Description Range Def.
Control
Mode
Addr.
Hex
Pg.
V/f
O
L
V
P
M

Table of Contents

Other manuals for YASKAWA V1000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA V1000 Series and is the answer not in the manual?

YASKAWA V1000 Series Specifications

General IconGeneral
ModelV1000 Series
SeriesV1000
Output Frequency0.1 to 400 Hz
Overload Capacity150% for 60 seconds
TypeAC Drive
Control MethodV/f Control
Input Voltage200-240V, 380-480V
Output Voltage0 to Input Voltage
Power Range0.1 to 18.5 kW
Horsepower0.2 to 25 HP
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit, Ground Fault
Communication InterfacesModbus RTU
EnclosureIP20
Ambient Temperature-10 to +50°C
Storage Temperature-20 to +60°C
Humidity5 to 95% RH (non-condensing)
Cooling MethodFan Cooled