B.2 Parameter Table
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07) 363
Parameter List
B
E4-14
<22>
Motor 2 Slip
Compensation
Gain
Function is the same as C4-01 for motor 1.
Magnifies the torque compensation gain. This
parameter does not typically require
adjustment, however, adjustments can be
made as follows:
Increase the setting when using a long motor
cable.
When using a motor with a smaller capacity
than the drive (the largest motor being used),
increase this setting.
If the motor begins to vibrate, adjust the value
set so that the output current doesn't exceed
the drive's rated output current when
operating at low speeds.
0.00 to
2.50
1.00
<2>
AA− 341 —
When operating at low speeds, adjust
this setting such that the output current
does not exceed the rated output
current for the drive.
—
E4-15
Torque
Compensation
Gain - Motor 2
Magnifies the torque compensation gain. This
parameter does not typically require
adjustment, however adjustments can be
made as follows:
When the motor cable is long, increase the
setting.
When using a motor with a smaller capacity
than the drive (the largest motor being used),
increase this setting.
If the motor begins to vibrate, adjust the value
such that the output current does not exceed
the drive's rated output current when
operating at low speeds.
1.00 to
2.50
1.10 A A − 341 —
E4-16 DELETE Available for Simple V/F with PG. - - - −− -—
E4-17 DELETE Available for Simple V/F with PG. - - - −− -—
E4-18 DELETE Available for Simple V/F with PG. - - - −− -—
E4-19 DELETE Available for Simple V/F with PG. - - - −− -—
E4-20 DELETE Available for Simple V/F with PG. - - - −− -—
E4-21 DELETE Available for Simple V/F with PG. - - - −− -—
E4-22 DELETE Available for Simple V/F with PG. - - - −− -—
E4-23 DELETE Available for Simple V/F with PG. - - - −− -—
E4-25 DELETE Available for Simple V/F with PG. - - - −− -—
E4-27 DELETE Available for Simple V/F with PG. - - - −− -—
No. Name Description Range Def.
Control
Mode
Addr.
Hex
Pg.
V/f
O
L
V
P
M