B.2 Parameter Table
YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07) 411
Parameter List
B
U1-16
Output Frequency
after Soft Start
Displays the output frequency following Soft
Start.
Units are determined by o1-03.
10 V: Max
frequency
0.01
Hz
AAA 53
U1-18 OPE Fault Parameter
Displays the parameter number for oPE
or Err (operator error) where the error
occurred.
No output
signal
available
–AAA61
U1-19
MEMOBUS/Modbus
Error Code
Displays the contents of a MEMOBUS/
Modbus error.
No output
signal
available
–AAA66
U1-24 Input Pulse Monitor
Displays the frequency of the Pulse Train
(RP) input.
32000 7D
U1-25 Software No. (Flash) Yaskawa Flash ID
No signal
output
available
4D
U1-26 Software No. (ROM) Yaskawa ROM ID
No signal
output
available
5B
U2: Fault Trace
Use U2 monitor parameters to view fault trace data.
U2-01 Current Fault Display of the current fault.
No signal
output avail.
–AAA80
U2-02 Previous Fault Display of the previous fault.
No signal
output avail.
–AAA81
No. Name Description Range Def.
Control
Mode
Addr.
Hex
V/
f
O
L
V
P
M
U1-18
=
00000000
1: CRC error
1: Data length
error
Not used
(normally 0)
1: Parity error
1: Overrun error
1: Framing error
1: Timed out
Not used
(normally 0)