11 TRIGger Subsystem
278 U2000 Series Programming Guide
TRIGger[1]:SOURce BUS|EXTernal|HOLD|IMMediate
This command configures the trigger system to respond to the specified
source. This command only selects the trigger source. Use the INITiate
command to place the power sensor in the wait for trigger state.
Syntax
NOTE
This command has been included for compatibility purposes. It has the same purpose as
TRIGger[:SEQuence[1]]:SOURce BUS|EXTernal|HOLD|IMMediate which
should be used in preference.
TRIG
:SOUR
1
EXT
HOLD
Space
IMM
BUS
?