QUICKDESIGNER Siemens •
••
• 221
Siemens S7300 MPI
The drawing shows the setup dialog box for Siemens S7300 MPI Protocol. The default setting for
Timeout is correct for most applications. See PLC user manual for more information about the Node
Range settings.
Source ID: Address of the QuickPanel
Destination ID: Address of the S7
Make sure the switch on the PC adapter is set to 19.2 kbps. See the PC adapter user manual for
instructions on setting the RS232 baud rate. Connect the PC adapter to the S7 and make sure the power
LED on the PC adapter is ON. The Activity LED on the PC adapter will flash when there is
communication between the adapter and the display.
Serial Port Parameters for the Display
Click the Port button to display the Serial Parameters dialog. The following settings are recommended
for Siemens S7MPI Protocol.
Elect. Format RS232
Baud Rate 19200
Data Bits 8
Parity Odd
Stop Bits 1
Handshake None
Click OK to return to the Project Setup dialog box.