Chapter 7: Maintenance
System Alarm Tables
7-32 011-003-991 EN
No Force Step The force step at energy value was not reached. Manually inspect the part. If the part is
acceptable, turn force stepping off. If the
part is not acceptable, you might want to
adjust your main parameter.
No Force Step The force step at power was not reached. Manually inspect the part. If the part is
acceptable, turn force stepping off. If the
part is not acceptable, you might want to
adjust your main parameter.
No Force Step The force step at external signal input not
received.
Manually inspect the part. If the part is
acceptable, turn force stepping off. If the
part is not acceptable, you might want to
adjust your main parameter.
No Force Step The collapse distance required for the force step
not reached.
Manually inspect the part. If the part is
acceptable, turn force stepping off. If the
part is not acceptable, you might want to
adjust your main parameter.
Preset Not
Available
Preset is recalled via external inputs and the
preset is not defined or is not allowed for the
control level.
Check control level availability for preset.
Preset is not defined.
Make sure presets do not exceed 16.
Pressure > Weld
Force
The weld force a cannot be reached because the
set pressure is too high.
2000a
2000dt
2000e
+ - Pwr Limit
Crossed
The suspect limits for power that you have entered
are reversed.
Change the suspect power limits through
the Alarm Information screen or Setup
menu.
2000a
2000dt
2000e
+ - Pwr Limit
Crossed
The reject limits for power that you have entered
are reversed.
Change the reject power limits through
the Alarm Information screen or Setup
menu.
2000a
2000dt
2000e
Pwr S/R Limit
Cross
The plus reject power limit is equal to or less than
the minus suspect power limit.
Change the +reject power limit or -
suspect power limit through the Alarm
Information screen or Setup menu.
2000a
2000dt
2000e
Pwr S/R Limit
Cross
The plus reject power limit is equal to or less than
the plus suspect power limit.
Change the +reject power limit or
+suspect power limit through the Alarm
Information screen or Setup menu.
2000a
2000dt
2000e
Pwr S/R Limit
Cross
The plus suspect power limit is equal to or less
than the minus reject power limit.
Change the +suspect power limit or -
reject power limit through the Alarm
Information screen or Setup menu.
Table 7.8 Setup Alarms and Messages, with Probable Cause
and Corrective Action (Continued)
Model
Display
Message
Alarm Condition/Cause Corrective Action