2000X energy Power Supply Chapter 7: Maintenance
Instruction Manual System Alarm Tables
011-003-991 EN 7-39
2000dt Missing Part
Conflict
The missing part minimum is equal to or greater
than the missing part maximum setting.
Change the missing part minimum and/or
the missing part maximum setting
through the Alarm Information screen or
Setup menu.
2000dt Missing Part
Conflict
The missing part maximum distance is equal to or
less than the minus reject absolute limit.
Change the missing part maximum
distance and/or the - reject absolute limit
through the Alarm Information screen or
Setup menu.
2000dt Missing Part
Conflict
The missing part
maximum distance is equal to or less than the
minus reject absolute limit.
Change the missing part minimum limit or
- reject absolute distance limit through
the Alarm Information screen or Setup
menu.
2000dt Missing Part
Conflict
The missing part
maximum distance is equal to or less than the
minus reject trigger limit.
Change the missing part minimum limit or
- reject trigger limit through the Alarm
Information screen or Setup menu.
2000dt Missing Part
Conflict
The missing part maximum distance is equal to or
less than the minus reject trigger limit.
Change the missing part maximum
distance or - reject trigger distance limit
through the Alarm information screen or
Setup menu.
2000dt Missing Part
Conflict
The missing part maximum distance is equal to or
less than the plus reject trigger limit.
Change the missing part maximum
distance or +reject trigger distance limit
through the Alarm information screen or
Setup menu.
2000dt Missing Part
Conflict
The missing part
minimum distance is equal to or greater than the
minus suspect absolute limit.
Change the missing part minimum
distance limit or - suspect absolute
distance limit through the Alarm
Information screen or Setup menu.
2000dt Missing Part
Conflict
The missing part
maximum distance is equal to or less than the
minus suspect
trigger limit.
Change the missing part maximum
distance limit or - suspect trigger limit
through the Alarm Information screen or
Setup menu.
2000dt Missing Part
Conflict
The missing part
minimum distance is equal to or greater than the
minus suspect trigger limit.
Change the missing part minimum
distance limit or - suspect trigger limit
through the Alarm Information screen or
Setup menu.
2000dt Missing Part
Conflict
The missing part
maximum distance is equal to or greater than the
plus reject absolute limit.
Change the missing part maximum
distance limit or +reject absolute limit
through the Alarm Information screen or
Setup menu.
Table 7.8 Setup Alarms and Messages, with Probable Cause
and Corrective Action (Continued)
Model
Display
Message
Alarm Condition/Cause Corrective Action

Table of Contents