Chapter 7: Maintenance
System Alarm Tables
7-40 011-003-991 EN
2000dt Missing Part
Conflict
The missing part
minimum distance is equal to or greater than the
plus reject absolute limit.
Change the missing part minimum
distance limit or +reject absolute distance
limit through the Alarm Information
screen or Setup menu.
2000dt Missing Part
Conflict
The missing part
minimum distance is equal to or less than the plus
reject trigger limit.
Change the missing part minimum
distance limit or +reject trigger distance
limit through the Alarm Information
screen or Setup menu.
2000dt Missing Part
Conflict
The missing part
maximum distance is equal to or less than the plus
suspect
absolute limit.
Change the missing part maximum
distance limit or +suspect absolute
distance limit through the Alarm
Information screen or Setup menu.
2000dt Missing Part
Conflict
The missing part
minimum distance is equal to or greater than the
plus suspect
absolute limit.
Change the missing part minimum
distance limit or +suspect absolute
distance limit through the Alarm
Information screen or Setup menu.
2000dt Missing Part
Conflict
The missing part
maximum distance is equal to or less than the plus
suspect trigger limit.
Change the missing part maximum
distance limit or +suspect trigger distance
limit through the Alarm Information
screen or Setup menu.
2000dt Missing Part
Conflict
The missing part
minimum distance is equal to or greater than the
plus suspect trigger limit.
Change the missing part minimum
distance limit or +suspect trigger distance
limit through the Alarm Information
screen or Setup menu.
2000dt Missing Part
Conflict
The missing part
minimum distance is equal to or greater than the
absolute distance cutoff.
Change the missing part minimum
distance limit or absolute cutoff through
the Alarm Information screen or Setup
menu.
2000dt Missing Part
Conflict
The missing part
maximum distance is equal to or greater than the
absolute distance cutoff.
Change the missing part maximum
distance limit or absolute cutoff through
the Alarm Information screen or Setup
menu.
2000dt Missing Part
Conflict
The missing part
minimum distance is equal to or greater than the
absolute distance setting. This alarm occurs in
absolute mode only.
Change the missing part minimum
distance limit or absolute distance
through the Alarm Information screen or
Setup menu.
2000dt Missing Part
Conflict
The missing part
maximum distance is equal to or greater than the
absolute distance setting. This alarm occurs in
absolute mode only.
Change the missing part maximum
distance limit or absolute distance
through the Alarm Information screen or
Setup menu.
Table 7.8 Setup Alarms and Messages, with Probable Cause
and Corrective Action (Continued)
Model
Display
Message
Alarm Condition/Cause Corrective Action