2000X energy Power Supply Chapter 7: Maintenance
Instruction Manual System Alarm Tables
011-003-991 EN 7-41
Preset Conflict Both the external selection of presets and
sequencing are turned on.
Turn off one of these.
2000dt Pretrigger Conflict The pretrigger
distance is equal to or greater than the minus
reject absolute limit.
Change the pretrigger distance or - reject
absolute limit through the Alarm
Information screen or Setup menu.
2000dt Pretrigger Conflict The pretrigger
distance is equal to or greater than the minus
suspect absolute limit.
Change the pretrigger distance or -
suspect absolute limit through the Alarm
Information screen or Setup menu.
2000dt Pretrigger Conflict The pretrigger
distance is equal to or greater than the plus reject
absolute limit.
Change the pretrigger distance or +reject
absolute limit through the Alarm
Information screen or Setup menu.
2000dt Pretrigger Conflict The pretrigger
distance is equal to or greater than the plus
suspect absolute limit.
Change the pretrigger distance or
+suspect trigger limit through the Alarm
Information screen or Setup menu.
2000dt Pretrigger Conflict The pretrigger
distance is equal to or greater than the plus reject
trigger limit.
Change the pretrigger distance or +reject
trigger limit through the Alarm Information
screen or Setup menu.
2000dt Pretrigger Conflict The pretrigger
distance is equal to or greater than the plus
suspect trigger limit.
Change the pretrigger distance or
+suspect trigger limit through the Alarm
Information screen or Setup menu.
2000dt Pretrigger Conflict The pretrigger
distance is equal to or greater than the minus
reject trigger limit.
Change the pretrigger distance or - reject
trigger limit through the Alarm Information
screen or Setup menu.
2000dt Pretrigger Conflict The pretrigger
distance is equal to or greater than the minus
suspect trigger limit.
Change the pretrigger distance or -
suspect trigger limit through the Alarm
Information screen or Setup menu.
2000dt Pretrigger Conflict The pretrigger
distance is equal to or greater than the
absolute cutoff distance
Change the pretrigger distance or
absolute cutoff through the Alarm
Information screen or Setup menu.
2000dt Pretrigger Conflict The pretrigger
distance is equal to or greater than the
absolute distance.
Change the pretrigger distance or
absolute distance through the Alarm
Information screen or Setup menu.
2000dt - R Trg > - R Abs The minus reject trigger limit is equal to or greater
than the minus reject absolute limit.
Change the - reject trigger limit and/or the
- reject absolute limit through the Alarm
Information screen or Setup menu.
2000dt +R Trg > +R Abs The plus reject trigger limit is equal to or greater
than the plus reject absolute distance limit.
Change the +reject trigger limit and/or the
+reject absolute distance limit through
the Alarm Information screen or Setup
menu.
Table 7.8 Setup Alarms and Messages, with Probable Cause
and Corrective Action (Continued)
Model
Display
Message
Alarm Condition/Cause Corrective Action