EasyManua.ls Logo

D-Link xStack DGS-3420 Series - Page 372

D-Link xStack DGS-3420 Series
1117 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
367
DGS-3420-28SC:admin#config ddm log enable
Command: config ddm log enable
Success.
DGS-3420-28SC:admin#
To configure DDM trap state to enable:
DGS-3420-28SC:admin#config ddm trap enable
Command: config ddm trap enable
Success.
DGS-3420-28SC:admin#
26-2 config ddm ports
Description
The command is used to configure the DDM settings of the specified ports.
Format
config ddm ports [<portlist> | all] [[temperature_threshold {high_alarm <degrees> | low_alarm
<degrees> | high_warning <degrees> | low_warning <degrees>} | voltage_threshold
{high_alarm <voltage> | low_alarm <voltage> | high_warning <voltage> | low_warning
<voltage>} | bias_current_threshold {high_alarm <milliampere> | low_alarm <milliampere> |
high_warning <milliampere> | low_warning <milliampere>} | tx_power_threshold {high_alarm
<mw_or_dbm> | low_alarm <mw_or_dbm> | high_warning <mw_or_dbm> | low_warning
<mw_or_dbm>} | rx_power_threshold {high_alarm <mw_or_dbm> | low_alarm <mw_or_dbm> |
high_warning <mw_or_dbm> | low_warning <mw_or_dbm>}] | {state [enable | disable] |
shutdown [alarm | warning | none]}]
Parameters
<portlist> - Enter the range of ports to be configured here.
all - Specify that all the optic ports’ operating parameters will be configured.
temperature_threshold - Specify the threshold of the optic module’s temperature in centigrade.
At least one parameter shall be specified for this threshold.
high_alarm - (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<degrees> - Enter the high threshold alarm value used here.
low_alarm - (Optional) Specify the low threshold for the alarm. When the operating parameter
falls below this value, the action associated with the alarm is taken.
<degrees> - Enter the low threshold alarm value used here.
high_warning - (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<degrees> - Enter the high threshold warning value here.
low_warning - (Optional) Specify the low threshold for the warning. When the operating

Table of Contents