xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
368
parameter falls below this value, the action associated with the warning is taken.
<degrees> - Enter the low threshold warning value here.
voltage_threshold - Specify the threshold of optic module’s voltage.
high_alarm - (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<voltage> - Enter the high threshold alarm value used here.
low_alarm - (Optional) Specify the low threshold for the alarm. When the operating parameter
falls below this value, the action associated with the alarm is taken.
<voltage> - Enter the low threshold alarm value used here.
high_warning - (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<voltage> - Enter the high threshold warning value here.
low_warning - (Optional) Specify the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<voltage> - Enter the low threshold warning value here.
bias_current_threshold - Specify the threshold of the optic module’s bias current.
high_alarm - (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<milliampere> - Enter the high threshold alarm value used here.
low_alarm - (Optional) Specify the low threshold for the alarm. When the operating parameter
falls below this value, the action associated with the alarm is taken.
<milliampere> - Enter the low threshold alarm value used here.
high_warning - (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<milliampere> - Enter the high threshold warning value here.
low_warning - (Optional) Specify the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<milliampere> - Enter the low threshold warning value here.
tx_power_threshold - Specify the threshold of the optic module’s output power.
high_alarm - (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<mw_or_dbm> - Enter the high threshold alarm value used here.
low_alarm - (Optional) Specify the low threshold for the alarm. When the operating parameter
falls below this value, the action associated with the alarm is taken.
<mw_or_dbm> - Enter the low threshold alarm value used here.
high_warning - (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<mw_or_dbm> - Enter the high threshold warning value here.
low_warning - (Optional) Specify the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<mw_or_dbm> - Enter the low threshold warning value here.
rx_power_threshold - Specify the threshold of optic module’s received power.
high_alarm - (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<mw_or_dbm> - Enter the high threshold alarm value used here.
low_alarm - (Optional) Specify the low threshold for the alarm. When the operating parameter
falls below this value, the action associated with the alarm is taken.
<mw_or_dbm> - Enter the low threshold alarm value used here.
high_warning - (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<mw_or_dbm> - Enter the high threshold warning value here.
low_warning - (Optional) Specify the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<mw_or_dbm> - Enter the low threshold warning value here.
state - (Optional) Specify the DDM state to enable or disable. If the state is disabled, no DDM