15 IN3 Input - - Low: <2.2 V, high: > 2.7 V. Can be used for INCA signals (signal state, trigger)
16 IN4 Input - - Low: <2.2 V, high: > 2.7 V. Can be used for INCA signals (signal state, trigger)
17 GND - - - Ground
18 LED_SYNC Output 5 V Status corresponds to the status of the LED SYNC (synchronization), dimensioned for
direct connecting Low Current LEDs to ground
19 LED_ETH Output 5 V Status corresponds to the status of the LED ETH (Ethernet, combined), dimensioned for
direct connecting Low Current LEDs to ground
20 Buzzer Output 5 V - Status as per internal acoustic signal generator, suitable for the direct connection of a Piezo
buzzer (e.g., Murata PKB24SPCH3601-B0)
21 LED_ON Output 5 V Status corresponds to the status of the LED ON (ES820.1/ ES830.1 operating state), dimen-
sioned for direct connecting Low Current LEDs to ground
22 LED_MEAS Output 5 V ES820.1: status corresponds to the status of the LED MEAS (measurement), dimensioned
for direct connecting Low Current LEDs to ground
LED_SYS Output 5 V ES830.1: status corresponds to the status of the LED SYS (status of the bypass model OS),
dimensioned for direct connecting Low Current LEDs to ground
23 LED_ERR Output 5 V Status corresponds to the status of the LED ERR (error status), dimensioned for direct con-
necting Low Current LEDs to ground
24 LED_MEM Output 5 V Status corresponds to the status of the LED MEM (memory), dimensioned for direct con-
necting Low Current LEDs to ground
LED_USER Output 5 V Status corresponds to the status of the LED USER (user-specific configuration in
INTECRIO), dimensioned for direct connecting Low Current LEDs to ground
25 LED_TEMP Output 5 V Status corresponds to the status of the LED TEMP (temperature), dimensioned for direct
connecting Low Current LEDs to ground
Pin Signal Type Logic I max.
[mA]
Meaning