APPENDIX
307
Slew Rate
Resolution
0.32mA/μs
3.2mA/μs
Slew Rate Setting
Accuracy
±(10% + 15μs)
Current Setting
Range
0~2.04A
0~20.4A
Current
Resolution
0.1mA
1mA
Current Accuracy
±0.4% F.S.
CONSTANT RESISTANCE MODE
Slew Rate
3.2 ~ 800mA/μs
Slew Rate
Resolution
3.2mA/μs
Slew Rate Setting
Accuracy
±(10% + 50μs)
Resistance
Setting Range
0.075Ω~300Ω(100W/16V)
3.75Ω~15kΩ(100W/80V)
Resistance
Resolution
0.333ms(100W/16V)
6.667μs(100W/80V)
Resistance
Accuracy
300Ω: ±(0.5%set + 0.1S)
15kΩ: ±(0.5%set + 0.01S)
MEASUREMENT
VOLTAGE READBACK
Range
0~16V
0~80V
Resolution
0.32mV
1.6mV
Accuracy
±(0.025%set + 0.025% F.S.)
CURRENT READBACK
Range
0~2A
0~20A
Resolution
0.04mA
0.4mA
Accuracy
±(0.05%set + 0.05% F.S.
*2
)
POWER READBACK
Range
0~10W
0~100W
Accuracy
±(0.1%set + 0.1% F.S.
*1
)
NOTE : *1 : Power F.S. = Vrange F.S. x Irange F.S.
*2 : F.S. = Full scale of H Range
PROTECTIVE
Over Power Protection
Range
1~102W
Resolution
0.5W
Accuracy
±(2%set + 0.25% F.S.)