The step resolution range is dependent on the load 
module and the range: 
Max resolution: Module dependent, see page 197 
Min resolution: Module dependent, see page 197 
When short mode is on, the load unit can simulate 
a short circuit.  
Shorting can be individually set for each channel 
when programming sequences. 
To initiate a short circuit manually, the short key is 
used. It can be used at any time during an 
operation. It will not affect the settings. After a 
short circuit has finished, the load unit will resume 
the previous operation.  
The short function can be set ON or OFF. When 
setting to ON, the short key is enabled. When 
setting to OFF, the short key is disabled.  
The short key can be set to toggle or hold. When 
pressed in toggle mode, shorts are toggled on and 
off. When pressed in hold mode, the key needs to 
be held to short the load. 
The Short Safety can be used to set the short 
operation mode. When setting to ON, the short 
function must be used in the case of Load ON. 
When setting to OFF, the short function can be 
used directly.