<Sysname> display alarm
Slot CPU Level Info
1 0 ERROR faulty
Table 34 Command output
Field Description
Slot
Slot that generated the alarm. If the alarm was generated by the chassis, this field
displays a hyphen (-).
Level
Alarm severity. Possible values include
ERROR
,
WARNING
,
NOTICE
, and
INFO
, in
descending order.
Info
Detailed alarm information:
• faulty—The slot is starting up or faulty.
• Fan n is absent—The specified fan is absent.
• Power n is absent—The specified power supply is absent.
• Power n is faulty—The specified power supply is faulty.
• The temperature of sensor n exceeds the lower limit—The temperature of
the specified sensor is lower than the low-temperature threshold.
• The temperature of sensor n exceeds the upper limit—The temperature of
the specified sensor is higher than the high-temperature warning threshold.
display clock
Use display clock to display the system time, date, time zone, and daylight saving time.
Syntax
display clock
Views
Any view
Predefined user roles
network-admin
network-operator
Examples
# Display the system time and date when the time zone is not specified.
<Sysname> display clock
10:09:00 UTC Fri 03/16/2015
# Display the system time and date when the time zone Z5 is specified.
<Sysname> display clock
15:10:00 Z5 Fri 03/16/2015
Time Zone : Z5 add 05:00:00
# Display the system time and date when the time zone Z5 and daylight saving time PDT are
specified.
<Sysname> display clock
15:11:00 Z5 Fri 03/16/2015
Time Zone : Z5 add 05:00:00
Summer Time : PDT 06:00:00 08/01 06:00:00 09/01 01:00:00