230
Parameters
slot slot-number: Specifies an IRF member device by its member ID. If you do not specify a member
device, this command displays temperature information for all member devices.
Examples
# Display information about all temperature sensors on the device.
<Sysname> display environment
System temperature information (degree centigrade):
----------------------------------------------------------------------
Slot Sensor Temperature Lower Warning Alarm Shutdown
1 hotspot 1 40 0 62 75 NA
1 hotspot 2 36 0 62 75 NA
1 hotspot 3 35 0 52 57 NA
1 hotspot 4 47 0 77 87 NA
Table 37 Command output
Field Description
System Temperature
information (degree centigrade)
Temperature information (°C).
sensor
Temperature sensor:
• hotspot—Hotspot sensor.
• inflow—Air inlet sensor.
• outflow—Air outlet sensor.
Slot Sensor position.
Temperature Current temperature.
Lower
Lower temperature limit. If the device does not support this field, this field
displays
NA
.
Warning
Warning temperature threshold. If the device does not support this field,
this field displays
NA
.
Alarm
Alarming temperature threshold. If the device does not support this field,
this field displays
NA
.
Shutdown
Shutdown temperature threshold. When the sensor temperature reaches
the limit, the system shuts down automatically. If the device does not
support this field, this field displays
NA
.
display fan
Use display fan to display fan tray operating status information.
Syntax
display fan [ slot slot-number [ fan-id ] ]
Views
Any view
Predefined user roles
network-admin
network-operator