EasyManuals Logo

HPE FlexFabric 5940 SERIES Fundamentals Command Reference

HPE FlexFabric 5940 SERIES
289 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #252 background imageLoading...
Page #252 background image
244
Syntax
fan prefer-direction slot slot-number { power-to-port | port-to-power }
undo fan prefer-direction slot slot-number
Default
The preferred airflow direction is from the power supply side to the port side.
Views
System view
Predefined user roles
network-admin
Parameters
slot slot-number: Specifies an IRF member device by its member ID.
power-to-port: Specifies the airflow direction from the power supply side to the port side.
port-to-power: Specifies the airflow direction from the port side to the power supply side.
Examples
# Specify port-to-power as the preferred airflow direction for member device 1.
<Sysname> system-view
[Sysname] fan prefer-direction slot 1 port-to-power
Related commands
display fan
hardware-resource switch-mode
Use hardware-resource switch-mode to set the hardware resource mode for the MAC address
table, ARP/ND table, and routing tables.
Syntax
hardware-resource switch-mode { 0 | 1 | 2 | 3 | 4 }
Default
The hardware resource mode is 0.
Views
System view
Predefined user roles
network-admin
Parameters
0: Sets the hardware resource mode to 0.
1: Sets the hardware resource mode to 1.
2: Sets the hardware resource mode to 2.
3: Sets the hardware resource mode to 3.
4: Sets the hardware resource mode to 4.

Table of Contents

Other manuals for HPE FlexFabric 5940 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexFabric 5940 SERIES and is the answer not in the manual?

HPE FlexFabric 5940 SERIES Specifications

General IconGeneral
BrandHPE
ModelFlexFabric 5940 SERIES
CategorySwitch
LanguageEnglish

Related product manuals