259
Examples
# Set the name of the device to R2000.
<Sysname> system-view
[Sysname] sysname R2000
[R2000]
system-working-mode
Use system-working-mode to set the system operating mode.
Use undo system-working-mode to restore the default.
Syntax
system-working-mode { advance | standard }
undo system-working-mode
Default
The device operates in standard mode.
Views
System view
Predefined user roles
network-admin
Parameters
advance: Sets the system operating mode to advanced.
standard: Sets the system operating mode to standard.
Usage guidelines
Change to the operating mode takes effect after a reboot.
Examples
# Set the system operating mode to advanced.
<Sysname> system-view
[Sysname] system-working-mode advance
Do you want to change the system working mode? [Y/N]:y
System working mode changed. For the change to take effect, save the running configuration
and reboot the device.
temperature-limit
Use temperature-limit to set the temperature alarm thresholds.
Use undo temperature-limit to restore the default.
Syntax
temperature-limit slot slot-number hotspot sensor-number lowlimit warninglimit [ alarmlimit ]
undo temperature-limit slot slot-number hotspot sensor-number
Default
To view the default settings, execute the undo temperature-limit and display environment
commands in turn.