4 Close the output bin door or doors.
5 Press .
270 error messages
Error code Description Action
271.03 Sensor (output pass through) lingering jam (high
capacity output and output expander)
The media reached the sensor (output pass
through) but did not clear it in the
specified
time.
Go to
“Sensor (output pass through) lingering
jam service check” on page 139.
271.04 Sensor (output pass through) late jam (high
capacity output and output expander)
The media is late reaching the sensor (output pass
through) within the
specified
time.
Go to
“Sensor (output pass through) late jam
service check” on page 157.
271.05 Sensor (output pass through) lingering jam (high
capacity output and output expander)
The media reached the sensor (output pass
through) but did not clear it in the specified time.
Go to
“Sensor (output pass through) lingering
jam service check” on page 139.
27x.14 Sensor (output pass through) static jam (high
capacity stacker, mailbox, oset stacker, and
output expander)
Media remains on the sensor (output pass
through) during the warmup sequence.
Go to
“Sensor (output pass through and
mailbox empty) static jam service check” on
page 141.
27x.14 Sensor (mailbox empty) static jam
Media remains on the sensor (mailbox empty)
during the warm up sequence.
27x.15 Sensor (output pass through) static jam (high
capacity stacker, mailbox, oset stacker, and
output expander)
Media remains on the sensor (output pass
through) during the warmup sequence.
27x.15 Sensor (mailbox empty) static jam
Media remains on the sensor (mailbox empty)
during the warm up sequence.
27x.29 Sensor (output pass through) lingering jam (high
capacity stacker, mailbox, oset stacker, and
output expander)
The media reached the sensor (output pass
through) but did not clear it in the
specified
time.
Go to
“Sensor (output pass through) lingering
jam service check” on page 139.
27x.50 Sensor (output pass through) lingering jam
(mailbox)
The media reached the sensor (output pass
through) but did not clear it in the specified time.
4062
Diagnostic information
138