Driving mode
5.3 Driving and parking the truck crane
5 - 50 3 302 819 en Operating manual
GMK3060
13.12.2018
The lamp (1) lights up if automatic cleaning is not performed in time. In this case
you can drive with an increased load for approx. 20 minutes. Perform a manual
cleaning if this is not possible or the light does not go out afterwards.
Manual cleaning Depending on the current operating mode of the crane, the operation is
performed on the CCS display in the driver's cab or the CCS display in the
crane cab.
Manual cleaning is only performed when all prerequisites specified here have
been fulfilled.
– The engine runs at idling speed – the idling speed must not be exceeded by
more than 50 rpm during the cleaning procedure.
– The accelerator pedal is not actuated.
– The service brake is not actuated.
– The parking brake is engaged.
• Ensure that all prerequisites remain satisfied during the entire cleaning
procedure.
• Select and confirm the symbol (1) – the Exhaust system menu opens.
• Select and confirm the symbol (1) – the cleaning process starts.
– The lamp (2) flashes.
– Lamp (3) lights up after the corresponding temperature increase.
The lamp (2) goes out when the cleaning procedure has finished.
The lamp (3) goes out once the exhaust system has cooled to the operating
temperature.
H
If the idling speed is exceeded by more than 50 rpm then the manual cleaning
procedure is interrupted and automatic cleaning can start, depending on the
degree of soiling.