Crane operation
11.5 Crane operation with main boom
Operating manual 3 302 819 en 11 - 103
GMK3060
13.12.2018
Checks before
starting work
When the ignition is turned on, CCS registers the displayed telescoping status
from the current status of the telescoping mechanism and the previously saved
locking and unlocking procedures.
Normally, the CCS detects differences between the current and the
displayed telescoping and displays the corresponding error message;
à Malfunctions in the telescoping mechanism, p. 14 - 19.
If a malfunction results in values being deleted, CCS can no longer calculate the
current telescoping and will not issue an error message.
• Before telescoping the first boom, compare the telescoping shown on the CCS
display with the current telescoping.
If the current telescope status is not correctly displayed, enter the current
telescope status;
à Current telescoping, p. 11 - 108.
s
S
Risk of damage to the telescoping mechanism!
Before the first telescoping, always check whether the CCS display is showing
the current telescoping.
This prevents the telescoping mechanism being damaged when telescoping.