Crane operation
11.5 Crane operation with main boom
11 - 118 3 302 819 en Operating manual
GMK3060
13.12.2018
Telescoping with
pre-selection
No additional telescoping menu needs to be opened for this type of telescoping
operation. All displays are shown in the Monitoring RCL menu. Pre-selection of
the telescope status has already been performed when entering the rigging mode
at the RCL;
à Pre-selecting telescoping, p. 11 - 44.
Pre-selection – Overview
The menu is opened with the symbol (1).
Four parameters can be entered for the loading
case.
The table shows all permissible telescopings (6)
and the associated parameter (7) for the entered
rigging mode.
A preselected telescope status (8) is shown on
the display (9) after confirmation.
After confirming the rigging mode, the display (1)
in the Monitoring menu shows the pre-selection.
Telescoping
• Switch on the telescoping mechanism.
• Move the control lever for the displayed
telescoping direction.
The display (2) shows the current position of the
telescoping cylinder.
2 Load weight
3 Working radius
4 Main boom length
5 Slewing range – MAXbase only
3 Extend
4 Retract
5 Display in the case of return runs (without a
telescopic section)