7.15.8.1 Object 0x3217: Cable break monitoring analog input 2
If this parameter is set to 1 the cable break monitoring for the analog input 2 is enabled.
7.15.8.2 Object 0x3228: Cable break monitoring analog input 3
If this parameter is set to 1 the cable break monitoring for the analog input 3 is enabled.
7.15.8.3 Object 0x3227: Cable break monitoring analog input 4
If this parameter is set to 1 the cable break monitoring for the analog input 4 is enabled.
If the 0…10 mA or the ±10 mA analog input type is used, no sensor wire cable break monitoring is available.
In this case only the sensor power supply monitoring for the analog inputs 2…4 is active.
If the 4…20 mA analog input type is used, cable break monitoring for all analog inputs is available.
AnalogInput
Index Sub-index Parameter name Data type Access Persistence Value range Default
0x3217 0 AnaInMonitorCurrent2 UINT8 rw Y 0…1 0
AnalogInput
Index Sub-index Parameter name Data type Access Persistence Value range Default
0x3228 0 AnaInMonitorCurrent3 UINT8 rw Y 0…1 0
AnalogInput
Index Sub-index Parameter name Data type Access Persistence Value range Default
0x3227 0 AnaInMonitorCurrent4 UINT8 rw Y 0…1 0