8.4.1.26 0x35: Task time exceeded
8.4.1.27 0x36: Parameter initialization error
8.4.1.28 0x37: Node identifier data memory corrupted
8.4.1.29 0x38: User data memory corrupted
Error Code: 0x35
Error Name: Task time exceeded
Description: The internal task time has exceeded. The number of tasks and the time to calculate
them exceeds the general time limitation. Not all tasks were calculated.
Severity of error: Medium
Action: Check the task time
Reduce the number of tasks (for example data logger, event handler)
Reduce interface usage
Change control mode
If the error occurs often or on a daily basis, even after reevaluation of all tasks, send
the valve back to factory for service.
Do not store your application in state 'HOLD' or 'ACTIVE'.
Error Code: 0x36
Error Name: Parameter initialization error
Description: Internal error during initialization of RAM parameter settings occurred
Severity of error: Major
Action: Restart the valve
If the error still occurs after restarting the valve, send the valve back to factory for
service.
Error Code: 0x37
Error Name: Node identifier data memory corrupted
Description: Internal error during initialization of extended parameter settings occurred
Severity of error: Major
Action: Restart the valve
If the error still occurs after restarting the valve, send the valve back to factory for
service.
Error Code: 0x38
Error Name: User data memory corrupted
Description: Internal error during initialization of customer parameter settings occurred
Severity of error: Major
Action: Restart the valve
If the error still occurs after restarting the valve, send the valve back to factory for
service.