(00292)H 8 - 9
8.4 Combined HX, GX Multi Camera Sync Recording with
the GX-HUB
This describes the connections and setting for when performing sync recording with the GX-HUB
and HX and GX cameras without using IRIG-B signals.
Connections for Multi Camera Sync Recording
When using the GX-HUB, connect any of PORT1~PORT4 on the GX-HUB to the HX or GX
camera J3 ETHERNET connector with the remote cable. Connect the external trigger to the
GX-HUB TRIG IN.
Procedures for Multi Camera Sync Recording
Settings (1) (2) below can be batch set in “GX-HUB Sync Recording” in the Recording
menu once HXLink is used for the camera connections. Refer to page 8-29 for details.
(1) Sync Settings (Options/Camera Connection Settings)
Set the HX,GX camera time to GX-HUB time.
(2) Input/Output Signals (Options/Camera Connection Settings)
Set the trigger input selection to TRIG2 and set the TRIG2 input polarity to current ON.
(If the TRIG2 input polarity is set to current OFF, the trigger signal is ON even if there is no
connection to the GX-HUB TRIG.IN terminal)