8 - 10 (00292)H
8.5 Combined Qcam, HX, GX, fx Multi Camera Sync
Recording
Refer to the GX-HUB user's manual for the connection method for combinations of HX, GX and
fx cameras using the M-HUB or GX-HUB.
■ Precautions for a Combined HX, GX, fx System
・One fx camera is needed for M-HUB control with a M-HUB system.
・If using IRIG-B signals, input the IRIG-B signals to the M-HUB IRIG.IN terminal.
・Input trigger signals to the M-HUB TRIG.IN terminal.
■ Procedures for Combined HX, GX, fx Multi Camera Sync Recording
Settings (1),(2) below can be batch set in “Combined Qcam, HX, GX, fx Sync Recording” in
the “Recording” menu once HXLink is used for camera connections. Refer to page 8-29 for
details.
(1) Sync Settings (Options/Camera Connection Settings)
Set the Qcam, HX, GX camera time to IRIG/M -HUB time.
(2) Input/Output Signals (Options/Camera Connection Settings)
Set the trigger input selection to TRIG2 and set the TRIG2 input polarity to current ON.
(If the TRIG2 input polarity is set to current OFF, the trigger signal is ON even if there is
no connection to the M-HUB TRIG.IN terminal)