1-1-37 Trunk Queuing Timeout Selection
General Description
Use this Memory Block to specify the time that a station with Trunk Queue set rings,
before the queue is automatically canceled.
Display
Settings
Notes
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
10s 20s 30s 60s
Programming Procedures
1 Go off-line.
2 Press LK1 + LK1 +
CG
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4
Press
G
to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E
to go back on-line.
When all trunks in a particular Trunk group are busy, the station user can dial an Access Code to queue on the
busy Trunk group. When a Trunk in that group becomes idle, the queued station is signaled.
System Mode
1
Submode
1
Data No.
37
PC Programming
¦
+BM
3 7 : T R U N K Q U E 1 0 s
T I M E D I S P L A Y
Setting
Data
Title
Data
No.