2 - 130 Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revison 1 Elite IPK
1-4-01 Automated Attendant First Digit PBR
Release Time Selection
General Description
Use this Memory Block to specify the time a Push Button Receiver (PBR) remains
connected after the Automated Attendant message is played when a calling party calls
in through an Automated Attendant trunk.
Display
Settings
Notes
LK 1 LK 2 LK 3 LK 4 LK 5 LK 6 LK 7 LK 8 The shaded
selection is the
default.
5s 10s
20s 30s 40s 50s 60s
Programming Procedures
1 Go off-line.
2 Press LK1 + LK4 +
JA
to access the Memory Block.
3 Press the corresponding CO/PBX line key to change the data option.
4 Press
G
to write the data and display the next Memory Block.
5 Program the next Memory Block or press
E
to go back on-line.
After PBR is connected, dialing must be completed in the specified time. After the first digit is dialed, interdigit
time (default 7 sec.) controls the PBR time. Dialing the third digit exceeds the 20 sec. default, and the PBR is
disconnected.
System Mode
1
Submode
4
Data No.
01
PC Programming
¦
+AU
0 1 : A A P B R T I M E 2 0 s
T I M E D I S P L A Y
Setting
Data
Data
No.
Title

Table of Contents

Other manuals for NEC Electra Elite IPK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NEC Electra Elite IPK and is the answer not in the manual?

NEC Electra Elite IPK Specifications

General IconGeneral
BrandNEC
ModelElectra Elite IPK
CategoryTelephone
LanguageEnglish

Related product manuals