1-1-50 CO/PBX Outgoing Digit Add
Assignment
General Description
Use this Memory Block to specify up to 10 additional digits when a trunk in the Trunk
group or Route Advance block assigned in Memory Block 1-1-49 (Networking Trunk
Group/Route Advance Assignment) is seized, and a number is dialed.
Display
Programming Procedures
1 Go off-line.
2 Press LK1 +
LK1 +
EK
to access the Memory Block.
3 Use dial pad to enter digits to be added for Closed Number Block 01.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data
H
to clear all data
B
+
J
to enter
,
B
+
L
to enter #
Default Values
Not Specified
4 Press
G
to write selected data and display the next Closed Number Block.
5 Repeat Steps 3 and 4 for each Closed Number Block. After data for the last Closed Number Block is written, the next Memory
Block is displayed.
6 Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number Memory Block Name
1-1-46
Access Code (1-Digit) Assignment
1-1-49
Networking Trunk Group/Route Advance Assignment
System Mode
1
Submode
1
Data No.
50
PC Programming
¦
+BCS
Data
No.
5 0 : 0 1 =
T I M E D I S P L A Y
Closed
Number
Block
01~16
Add
Digit
10 Max.